Domingo-Pardo, C.*; Abbondanno, U.*; Aerts, G.*; lvarez, H.*; Alvarez-Velarde, F.*; Andriamonje, S.*; Andrzejewski, J.*; Assimakopoulos, P.*; Audouin, L.*; Badurek, G.*; et al.
Physical Review C, 75(1), p.015806_1 - 015806_9, 2007/01
Times Cited Count:34 Percentile:86.89(Physics, Nuclear)The neutron capture cross section of Pb has been measured at the CERN n_TOF installation with high resolution in the energy range from 1 eV to 440 keV. In the interval between 100 keV and 440 keV we report the average cross section. The background in the entire energy range was reliably determined from the measurement of a Pb sample. We obtain a Maxwellian average capture cross section for Pb at = 30 keV of 79(3) mb, in agreement with previous experiments. However our cross section at = 5 keV is about 35 % larger than the values reported so far. The implications of the new cross section for the -process abundance contributions in the Pb/Bi region are discussed.
Domingo-Pardo, C.*; Abbondanno, U.*; Aerts, G.*; lvarez, H.*; Alvarez-Velarde, F.*; Andriamonje, S.*; Andrzejewski, J.*; Assimakopoulos, P.*; Audouin, L.*; Badurek, G.*; et al.
Physical Review C, 74(2), p.025807_1 - 025807_10, 2006/08
Times Cited Count:47 Percentile:90.36(Physics, Nuclear)The neutron capture cross section of Bi has been measured at the CERN n_TOF facility by employing the pulse-height-weighting technique. Improvements over previous measurements are mainly because of an optimized detection system, which led to a practically negligible neutron sensitivity. Because Bi is the last stable isotope in the reaction path of the stellar s-process, the Maxwellian averaged capture cross section is important for the recycling of the reaction flow by alpha decays. In the relevant stellar range of thermal energies between = 5 and 8 keV our new capture rate is about 16% higher than the presently accepted value used for nucleosynthesis calculations. The present cross section measurement is also of relevance for the design of accelerator driven systems based on a liquid metal Pb/Bi spallation target.
Aerts, G.*; Abbondanno, U.*; lvarez, H.*; Alvarez-Velarde, F.*; Andriamonje, S.*; Andrzejewski, J.*; Assimakopoulos, P.*; Audouin, L.*; Badurek, G.*; Baumann, P.*; et al.
Physical Review C, 73(5), p.054610_1 - 054610_10, 2006/05
We have measured the neutron capture reaction yield of Th at the neutron tim-of-flight facility n_TOF at CERN in the energy range from 1 eV to 1 MeV. The average capture cross section has been extracted in the energy range from 4 keV up to 1 MeV with an overall accuracy better than 4 %. An independent IAEA evaluation shows good agreement with the data.
Aerts, G.*; Abbondanno, U.*; lvarez, H.*; Alvarez-Velarde, F.*; Andriamonje, S.*; Andrzejewski, J.*; Assimakopoulos, P.*; Audouin, L.*; Badurek, G.*; Baumann, P.*; et al.
Physical Review C, 73(5), p.054610_1 - 054610_10, 2006/05
Times Cited Count:45 Percentile:89.83(Physics, Nuclear)We have measured the neutron capture reaction yield of Th at the neutron time-of-flight facility n_TOF at CERN in the energy range from 1 eV to 1 MeV. The average capture cross section has been extracted in the energy range from 4 keV up to 1 MeV with an overall accuracy better than 4%. An independent IAEA evaluation shows good agreement with the data.
Terlizzi, R.*; Abbondanno, U.*; Aerts, G.*; lvarez, H.*; Alvarez-Velarde, F.*; Andriamonje, S.*; Andrzejewski, J.*; Assimakopoulos, P.*; Audouin, L.*; Badurek, G.*; et al.
AIP Conference Proceedings 819, p.283 - 287, 2006/03
We measured the neutron capture cross section of La relative to Au in the energy range of 0.6 eV to 9 keV at n_TOF, the neutron time-of-flight facility at CERN. The data were fitted using R-matrix formalism to extract resonance parameters which were used to calculate average level spacings. The data were used to determine Maxwellian-averaged neutron capture cross sections which, in turn, were used to calculate the La abundance synthesized in a steller model of the main component of the process.
Cano-Ott, D.*; Abbondanno, U.*; Aerts, G.*; lvarez, H.*; lvarez-Velarde, F.*; Andriamonje, S.*; Andrzejewski, J.*; Assimakopoulos, P.*; Audouin, L.*; Badurek, G.*; et al.
AIP Conference Proceedings 769, p.1442 - 1445, 2005/05
Accurate and reliable neutron cross section data for actinides are necessary for the proper design, safety reguartion and precise performance assessment of transmutaion devices. In particular, the neutron capture cross sections of Np, Pu and Am play a key role in the design and optimization of a strategy for the Nuclear Waste Transmutation. The listed cross sections have been measured in 2004 at n_TOF with a high accuracy due to a combination of features unique in the world.